iFastBP® NIBP Technology
iFastBP® is the trademark of NIBP measurement technology that is belong to Witleaf. iFastBP® technology is a whole technology system that include the basic theory of NIBP measurement and the advantage features for example ,accuracy,anti-motion,wide range application and low perfusion measurement ability and so on.
iFastBP® based on the oscillation method. iFastBP® keeps been upgraded from clinical feedback to get the best clinical application satisfaction.

Oscillation Theory
The Oscillation theory as follows:
iFastBP® system will increase the cuff pressure until the arterial pulse is blocked then the system will deflate the cuff pressure by the valve that integrated in the system.During deflation the iFastBP® system will detect the arterial pulse until there is a whole arterial pulse wave that can calculate the blood pressure.After the system determine the Mean,SYS and DIA position then the related cuff pressure is the blood pressure for this cycle measurement of NIBP.
iFastBP® NIBP Technology—advantage
Accuracy
The reliable and accuracy reading from the NIBP equipment is very important for the clinical to evaluate the patient's condition and the safety during monitoring in OR, ICU and so on. The iFastBP® clinical database guarantee the accuracy of NIBP measurement.Compared with the general NIBP measurement system which determine the blood pressure with the same way for all kinds of patient, iFastBP® depends on the different group of people(The group will determine by the system automatically depends on the patient arterial pulse waveform shape) to use the more better match calculation method which is integrated with the system to get more better accuracy result for different patient, how the system build the database for different group of patient as follows:
iFastBP® system get the arterial pulse during inflation and deflation of the cuff pressure,at the same time we get the reading of the related patient blood pressure by two doctors determine by stethoscope(This is the standard for determine patient blood pressure for clinical diagnosis that accepted by all over the world). Then the iFastBP® system build the relationship between the arterial pulse with the blood pressure.With more and more kinds of arterial pulse the system can determine the blood pressure with the more suitable way that can get more better accuracy NIBP measurement result compared with the general system to increase the safety monitoring of the patient.

Intelligent Method
iFastBP® intelligent method include inflation,deflation and arterial pulse sample together.This method makes the measurement speed more faster and let the patient feel more comfortable during measurement.Together with more comfortable for the patient also can save the waiting time of doctors or nurse during NIBP measurement then to save the total cost during patient monitoring.
Intelligent inflation depends on the patient SYS to set the target inflation cuff pressure.Benefit from this method iFastBP® system can avoid the cuff pressure cannot block the arterial pulse or too high for blocking the arterial pulse of the patient.Depends on this feature the iFastBP® system can determine the blood pressure for this cycle measurement without inflation again, so the measurement time is saved and more comfortable feeling of the patient is given during NIBP measurement. Intelligent deflation and arterial pulse sample method detect the noise from motion and the arterial pulse condition to adjust the deflation parameter. With this method the iFastBP® system can get more accuracy arterial pulse during measurement,then iFastBP® system can increase the ability to get the NIBP result for avoiding measurement failure.Benefit from this advantage feature with iFastBP® system can decrease the complaint from clinical.Compare with the general method during there is motion noise the advantages of iFastBP® system as follows:
Intelligent inflation depends on the patient SYS to set the target inflation cuff pressure.Benefit from this method iFastBP® system can avoid the cuff pressure cannot block the arterial pulse or too high for blocking the arterial pulse of the patient.Depends on this feature the iFastBP® system can determine the blood pressure for this cycle measurement without inflation again, so the measurement time is saved and more comfortable feeling of the patient is given during NIBP measurement. Intelligent deflation and arterial pulse sample method detect the noise from motion and the arterial pulse condition to adjust the deflation parameter. With this method the iFastBP® system can get more accuracy arterial pulse during measurement,then iFastBP® system can increase the ability to get the NIBP result for avoiding measurement failure.Benefit from this advantage feature with iFastBP® system can decrease the complaint from clinical.Compare with the general method during there is motion noise the advantages of iFastBP® system as follows:

Widely Application
iFastBP® system with wide signal range technology can get more better accuracy during various application for example the intensive care with the low perfusion,neonate monitoring with motion noise.The following picture shows the general method with the iFastBP® system during high arterial pulse condition which is very easy to meet during neonate monitoring,
The picture 2 shows the general method with the iFastBP® system during high arterial pulse condition which is very easy to meet during neonate monitoring:
The picture 2 shows the general method with the iFastBP® system during high arterial pulse condition which is very easy to meet during neonate monitoring:

From the picture 3 and the table we can find that the iFastBP® system can let us benefit more than the general method, especially in the neonate monitoring that more easier to meet the simulated condition.

From the picture 4 the test result shows that the iFastBP® system can get better accuracy and reliable measurement than the general method.With the clinical investigation also shows that the iFastBP® system can decrease the clinical complaint than the general method.

From the picture 5 comparative clinical feedback in the acute and critical care setting suggests that the use of iFastBP® is superior to conventional blood pressure monitoring technology, receiving a much lower percentage of clinical complaints.

Anti-Motion
iFastBP® system is equipped with the real-time algorithm and frequency algorithm together. During NIBP measurement these two algorithms work parallel which can make the measurement more reliable and keep the accuracy if there is noise.If the iFastBP® system finds that there is arterial pulse missing or abnormal the frequency method will start to compensate the arterial pulse to get a completed arterial pulse for determining the blood pressure.With this advantage feature the iFastBP® system can get reliable and accurate blood pressure readings which is very useful for bedside monitoring,remote monitoring, SPOT checking,Monitoring during movement and neonate monitoring. Tested together with the general method iFastBP® system get better clinical feedback, shown as follows:

iFastBP® NIBP technologh—Clinical benefit

For the monitoring during movement and remote monitoring in clinical the iFastBP® system can get more powerful ability for avoiding measurement failure, and for bedside monitoring, and pediatric/neonate monitoring the iFastBP® system can get more reliable readings. This advantage feature can avoid fake alarms during NIBP monitoring in various clinical application to save the cost of nurses and doctors' energy.